Download Tecumseh VSAG511ZXTHN Performance Data Sheet
Transcript
VSAG511ZXTHN TPC___preliminary October 14, 2011 Parts/Specifications STANDARD Unit BOM Unit MODEL 32L2642-2E VSAG511ZXTHN Refrigeration RANGE Design Pressure Low Design Pressure High Volts - HZ - Ph Voltage Range Min. Circuit Ampacity Max. Fuse Size -40°F to 10°F 181 450 200-230V 3~ 60HZ 180 - 253 14.11 25 Compressor Compressor Compressor Compressor VSAG494ZXT VS121RT-008-A4 80 10.00 MODEL BOM LRA RLA OverLoad Relay Run Capacitor Run Capacitor Rating Start Capacitor Start Capacitor Rating Contactor INTERNAL Unit Drawing Wiring no Fan controls DGU1950-L301 WD23-2XT2L 91014B OPTIONAL Fan Motor Fan Motor Qty Fan Motor RLA Fan Blade Fan Guard Shroud 810F050C20 2 0.7 51568-1 70831 70648-2 High Pressure switch Low Pressure Control Dual Pressure Conrol 84095-2L 84026-2 Condenser Head Master Valve Check Valve Process Valve Liquid Valve Suction Valve 50858 70083 56626 Receiver Receiver Qty Accumulator Liquid Filter Sight Glass Suction Filter 51099-2L 1 TK00042000 52000-084D 70084-2 70822-5S CrankCase Heater 14947869 Adjustable Fan Ctrl (A) LAFC-001 Defrost Timer (Tn) LTCG-T2 Receiver Heater (R) LHR-222 Solenoid Valve (S) KSVC-285 Disconnect (D) KDSG-301 BOM INDEX DESCRIPTION 31529-2 32xYYYY- 2ERA(F)TnDS E Enclosure R Receiver Heater A Adjustable fan control F Fixed fan Control T1 Defrost timer option T2 Defrost timer & Defrost Heaters Contactor D Disconnect S Solenoid liquid Valve (supplied loose) NOTES IMPORTANT: COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. USE COPPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEUERS DE CUIVER SEULEMENT.) 4 3 X N 1 2 DEFROST CONTROL RANCO 8145-xx PRECISION 6145-xx FAN 1 DEFROST HEATERS CONTACTOR COIL FIELD WIRING NOTES 1. ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. 2. CONNECT INCOMING POWER LEADS FROM POWER SUPPLY TO L1, L2, AND L3 IN COMPRESSOR CONTACTOR OR TO L1, L2 AND L3 IN DISCONNECT SWITCH (IF PROVIDED). USE COOPER CONDUCTORS ONLY. (EMPLOYER DES CONDUCTEURS DE CUIVER SEULEMENT.) PROVIDE EQUIPMENT GROUNDING CONDUCTOR. USE 75°C (MIN.) WIRING 3. DEFROST HEATERS LOADS SHOULD NOT BE HIGHER THEN THE MAXIMUM HEATERS LOAD INDICATED ON THE UNIT LABEL. DEFROST HEATERS TO BE CONTROLLED WITH A CONTACTOR AS SHOWN ON THE DIAGRAM. COMPRESSOR CONTACTOR NC AUXILIARY SWITCH FAN 2 GENERAL NOTES: SOLENOID LIQUID INJECTION A. CONTACTOR COIL CIRCUIT IS FACTORY CONNECTED TO 230 V SOURCE IN PANEL AS SHOWN B. COMPRESSOR EQUIPPED WITH AN INTERNAL OVERLOAD PROTECTOR. ALLOW TIME FOR RESET. COMPRESSOR CONTACTOR NO AUXILIARY SWITCH FC COMPRESSOR CONTACTOR COIL see note A HP LP FAN CONTROL DT LP LOW PRESSURE CONTROL TERMINAL BOARD P1 RECEIVER HEATER L2 L1 L3 T1 T3 F1 F2 HP THERMOSTAT HIGH PRESSURE SWITCH POWER SUPPLY 208-230 / 60 / 3 L3 T3 L2 T2 L1 T1 DT DISCHARGE LINE THERMOSTAT FACTORY COMPONENTS GRD CRANK CASE HEATER COMPRESSOR CONTACTOR L1 L2 L3 T1 T2 T3 DEFROST HEATERS CONTACTOR L1 L2 L3 T1 T2 T3 OPTIONAL FACTORY COMPONENTS OPTIONAL FIELD COMPONENTS BLACK C S R RED YELLOW CONDENSING UNIT WIRING, 230V 60Hz 3 Ph, Liquid Injection Solenoid, Fan control, T1 & T2 defrost options REL REVISION L:\~ Andreea temp\ZZ Low Temp Scroll Datasheets\WORD_datasheets\Outdoor units\VSAG511ZXTHN_preliminary.doc MAR. 11, 2011 COMPRESSOR TERMINAL WD23-2XT2L 14/10/2011