clear lldp
Defaults
None.
Mode
Switch command, read‐write.
Example
This example configures the management address, MED capability, and MED location identification TLVs to be sent in LLDPDUs by port fe.1.1.
B2(rw)->set lldp port tx-tlv mgmt-addr med-cap med-loc fe.1.1
clear lldp
Use this command to return LLDP parameters to their default values.
Syntax
clear lldp {all | tx-interval | hold-multiplier | trap-interval | med-fast-repeat}
Parameters
all
Returns all LLDP configuration parameters to their default values, including port LLDP configuration parameters.
tx‐interval
Returns the number of seconds between transmissions of LLDP frames.to the default of 30 seconds.
hold‐multiplier
Returns the multiplier to apply to the transmit interval to determine the time‐to‐live value to the default value of 4.
trap‐interval
Returns the minimum time between LLSP trap transmissions to the default value of 5 seconds.
med‐fast‐repeat
Returns the number of fast start LLDPDUs to be sent when an LLDP‐
MED endpoint device is detected to the default of 3.
Defaults
None.
Mode
Switch command, read‐write.
Example
This example returns the transmit interval to the default value of 30 seconds.
B2(rw)->clear lldp tx-interval
clear lldp port status
Use this command to return the port status to the default value of both (both transmitting and processing received LLDPDUs are enabled).