CHAPTER 7 EXCEPTION PROCESSING 7.4.9 Bus Error exception Cause A Bus Error exception is raised by board-level circuitry for events such as bus time-out, local bus parity errors, and invalid physical memory addresses or access types. This exception is not maskable. A Bus Error exception occurs only when a cache miss refill, uncached reference, or unbuffered write occurs synchronously. Processing The common interrupt vector is used for a Bus Error exception. The IBE or DBE code in the ExcCode field of the Cause register is set, signifying whether the instruction caused the exception by an instruction reference, load operation, or store operation. When the MIPS16 instruction is disabled, the EPC register contains the address of the instruction that caused the exception. However, if this instruction is in a branch delay slot, the EPC register contains the address of the preceding jump or branch instruction, and the BD bit of the Cause register is set to 1. When the MIPS16 instruction is enabled, the EPC register contains the address of the instruction that caused the exception, and the least significant bit stores the ISA mode in which an exception occurs. However, if this instruction is in a branch delay slot or is the instruction following the Extend instruction, the EPC register contains the address of the preceding jump or Extend instruction, and the BD bit of the Cause register is set to 1. Servicing The physical address at which the fault occurred can be computed from information available in the System Control Coprocessor (CP0) registers. • If the IBE code in the Cause register is set (indicating an instruction fetch), the virtual address is contained in the EPC register (or 4 + the contents of the EPC register if the BD bit of the Cause register is set to 1). • If the DBE code is set (indicating a load or store), the virtual address of the instruction that caused the exception is saved to the EPC register. The virtual address of the load and store instruction can then be obtained by interpreting the instruction. The physical address can be obtained by using the TLBP instruction and reading the EntryLo register to compute the physical page number. At the time of this exception, the kernel reports the UNIX SIGBUS (bus error) signal to the current process, but the exception is usually fatal. User’s Manual U14272EJ1V0UM00 187
Related documents
manual de usuario del simulador de instrucciones mips r-4000
VR4181™
cache
ST-Realizer-II user manual (for ST62 & ST7 8-bit MCUs)
Using PDtrace™ with SDE and System Navigator™ for MIPS® Cores
Errata Sheet
Errata Sheet
Errata for MIPS R4000/R4400 Microprocessor User`s Manual
YAMON™ User`s Manual
CPU Instruction Set Details
IDT MIPS Microprocessor Family Software Reference Manual
VR Series 64-/32-Bit Microprocessor Programming Guide AN