Download CubeSuite Ver.1.40 Integrated Development Environment User`s
Transcript
CubeSuite Ver.1.40 APPENDIX A WINDOW REFERENCE [How to open] - From the [View] menu, select [Disassemble] >> [Disassemble1 - 4]. [Description of each area] (1) Event area The lines for which events can be set are shown with the background color in white (this mean that events cannot be set for those lines whose background color in gray). In addition, the Event mark corresponding to an event that has been currently set is displayed. This area is provided with the following functions. (a) Setting/deleting breakpoints By clicking where you want to set a breakpoint with the mouse, the breakpoint can be set easily. The breakpoint is set to the instruction at the start address of the clicked line. Once the breakpoint is set, the Event mark is displayed at the line that is set. In addition, the detailed information about the set breakpoint is reflected in the Events panel. When this operation is performed at a place where any one of the event marks is already being displayed, that event is deleted and the setting of breakpoints cannot be done. Note that the setting of events can be done only for those lines where the background color is shown in white. See "2.8.2 Stop the program at the arbitrary position (breakpoint)" for details on how to set the breakpoint. (b) Changes event status Event status can be changed from the following menu displayed by right-clicking the event mark. Enable Event Changes the selected event state to a Valid state. Event occurs when the specified condition is met. When the event mark ( ) which indicates that multiple events have been set is selected, all of the events that have been set are enabled. Disable Event Changes the selected event state to an Invalid state. Event does not occur when the specified condition is met. When the event mark ( ) which indicates that multiple events have been set is selected, all of the events that have been set are disabled. Delete Event Deletes the selected event. When the event mark ( ) which indicates that multiple events have been set is selected, all of the events that have been set are deleted. View Event Detailed Setup Opens the Events panel to display the detailed information of the selected event. (c) Pop-up display By superimposing the mouse cursor on the Event mark, the name of the event, the detailed information for the event and the comments added to the event are pop-up displayed. When multiple events have been set in the applicable place, information for each event, up to a maximum of three events, is listed and displayed. (2) Address area The address per line to start disassembling is displayed (hexadecimal number notation fixing). In addition, the current PC mark ( ) that corresponds to the current PC position (PC register value) is displayed. The address width corresponds to the one in memory space of the specified microcontroller in the project. R20UT0264EJ0100 Rev.1.00 Oct 01, 2010 Page 249 of 538
Related documents
RL78 Debug - Renesas Electronics
78K0 Debug - Renesas Electronics
V850 Debug - Renesas Electronics
IECUBE2 for FX4 uPD70F3555-uPD70F3560, uPD70F4007
SM+ for 78K0R, System Simulator for 78K0R
QB-70F3534-PD QB-70F3532-PD
CubeSuite Ver.1.40 Integrated Development Environment User`s
ORIENTEK TR600 OTDR
PDF document - Renesas Electronics
User`s Manual(Preliminary) IECUBE2 main (QB
In Circuit Scope Plus (ICS++ W1004) User`s manual
V850 JTAG OCD Checker User`s Manual