Download ManualV3 - Electromate

Transcript
Because the average speed on this interval equals 15,000 counts/sec, the
deceleration interval is 1500 counts. Accordingly, the coordinates of the points
B1 and D1 are (4500,0) and (-4500,2000) respectively.
To change the feedrate along the path, we break the segments AB and CD into
two parts each and attach a vector speed to each segment by adding the
symbol <n at the end of the segment instruction. This sets the attached speed
to n counts/s. The resulting program is shown on the following page.
Instruction
Interpretation
#MOVE
VMXY
VP 4500,0<20000
Label
Specify XY plane
Move to Point B1 at
speed 20000
Move to Point B at
speed 10000
Move to Point C - no
speed change
Move to Point D1 at
speed 20000
Move to Point D at
speed 10000
Move to Point E
Move to Point A at
speed 20000
End of path
Vector acceleration
Vector deceleration
Start motion
End of program
VP 6000,0<10000
CR 1000,270,180
VP -4500, 2000<20000
VP -6000,2000<10000
CR 1000,90,180
VP 0,0<20000
VE
VA 100000
VD 100000
BGS
EN
163