Download FermaT Workbench User Guide - Software Migrations Limited
Transcript
Page 124 All the Fermat Workbench tables are held in the project Config folder. Customisation must be preformed after defining the project and before Importing any files. The following tables may be customised. complex.tab entry.tab macros.tab routine.tab udata.tab ulinkage.tab uopcodes.tab UserMacro.tab ustmac.tsb version.tab. 30.1 complex.tab This table holds the default setting for the complexity code, which gives an indication of the complexity of the program. The complexity code is derived from the value of the McCabe Index. McCabe = count of branches + count of calls to sub-routines + 1 The current default settings are A B C D E F G H I 5 10 50 100 200 350 600 800 > 800 Version: Issued Status: Confidential © 2008 Software Migrations Limited User Guide 138