Download Chapter 2 EXECUTIVE CONTROL COMMANDS

Transcript
TICTV
User’s Reference Manual
Bulk Data Entry
TICTV
Defines translational velocity initial conditions for the structural model for Direct or Modal Transient
Response analyses.
Format and Example:
1
2
TICTV
-cont-
SID
TICTV
3
4
5
6
7
8
9
10
CID
A
V1
V2
V3
GID1
-cont-
GRID ID LIST
1000
THRU
1
10.0
1.0
0.0
0.0
1
3399
Field
Contents
Data Range
Default
SID
Set identification number. [1,2]
Integer>0
Required
CID
Coordinate system identification number in which V
is defined.
Integer≥0
0
A
The value of translational velocity.
Real
Required
Vi
Components of a vector, in coordinate system CID,
defining the direction of translational velocity.
Real
1.,0.,0.
GID1,
Initial GRID point, and list of one or more GRID
points, which will have velocity initial conditions
computed.
Integer>0
Required
GRID ID
LIST
Remarks:
1.
Transient initial condition sets must be selected in the Case Control packet with the command:
IC = SID
Initial conditions are the sum of all data from TIC, TICRV, and TICTV Bulk Data entries.
2.
3.
Initial conditions for components not specified on TIC, TICRV, and TICTV entries are assumed
zero. Therefore, if an IC command is not present in the Case Control packet, all initial conditions
are assumed zero.
Options on the Case Control command IC may be used to cause the automatic calculation of
initial conditions when applie loads are non-zero at t=0. Also, initial conditions may also be
computed automatically for Modal Transient Response analyses using Bulk Data entry
PARAM,NRB.
UAI/NASTRAN
BULK DATA 7-381
7
BULK