Download Chapter 2 EXECUTIVE CONTROL COMMANDS
Transcript
User’s Reference Manual A double precision number must contain both a decimal point and an exponent with the character D such as: 3.5D1 or 2.7D+1 or 70.D-1 Double precision data values are only allowed in a few special cases, i.e. when using DMI and DMIG Bulk Data entries. Character data values consist of one to eight alphanumeric characters, the first of which must be alphabetic. Normally field 10 is used to signify that a continuation entry will follow the current parent entry. If the current entry can not have a continuation, field 10 may be used for optional user identification data. The continuation entry contains the symbol + in column 1 followed by the same seven characters that appeared in positions 74-80 of field 10 of the parent entry. This allows the Bulk Data packet to be input with entries out of alphanumeric sort. Also, the continuation entries need not follow the parent when continuation mnemonics are used. Although the + sign is not specifically required in column 73 of the parent when the fixed-field format is used, its use is good practice. The + character is required when using the free-field input form as presented earlier in Section 7.1.1. The fixed-field data entry should be more than adequate for data normally associated with structural engineering problems. Since abbreviated forms of floating point numbers are allowed, up to seven significant decimal digits may be used in an eight-character field. Occasionally, however, the input is generated by another computer program or is available in a form where greater precision is desired. In this case, a high-precision format with a sixteen (16) character data field is provided, as described next. 7.1.3 High-Precision Data Entry Each entry for the high precision format requires the equivalent of two 80 character records as shown below: 7 BULK 1a 1 8 2 9 1b 1 8 3 24 25 6 9 4 40 41 7 24 25 5 56 57 8 40 41 72 73 80 9 56 57 10a 10b 72 73 80 A high-precision entry is denoted by placing the symbol * after the mnemonic in field 1a and some unique character configuration in the last 7 columns of field 10a. The second physical record contains the symbol * in column 1 followed by the same seven characters that appeared after column 73 in field 10a of the first entry. The second record may, in turn, be used to point to a high-precision fixed-field continuation entry, depending on whether the continuation entry contains the symbol * or the symbol + in column 1. Note that the two physical records which define a single logical high-precision entry must always appear consecu- 7-6 BULK DATA UAI/NASTRAN
Related documents
User Manual
Denon DN-C680 CD Player User Manual
modelação e implementação de processos na plataforma
Manuela Calado - VII Jornadas Técnicas de Segurança no Trabalho
DCAN Macro Version B2 Preliminary User`s Manual
Manuela Calado
User manual of the Work Examiner
National Instruments 370755B-01 User's Manual
Runstream - Shell Buckling
pontifícia universidade católica de minas gerais
CBLIO43-x, CBLIO52-x, CBLIO43DE-x and CBLIO52DE-x
CLBIO4352DEx1 USER`S MANUAL