MATT1 User’s Reference Manual Bulk Data Entry MATT1 Defines table references for isotropic material properties which are temperature-dependent. Format and Example: 1 2 3 4 5 6 7 MATT1 -cont- MID TID7 TID1 TID8 TID2 TID9 TID3 TID4 TID5 MATT1 +A 118 133 163 Field 8 9 TID6 10 -cont- +A Contents Data Range Default MID Material property identification number. [1,2] Integer>0 Required TIDi Table identification numbers. Integer>0 [2,3] Remarks: 1. Material temperature dependency information are used only when a temperature distribution for materials is defined by using TEMP(MATERIAL) or TEMP(BOTH) Case Control commands. 2. The TIDi correspond to the entries defined on the MAT1 Bulk Data entry with the same MID, and they are positional. A blank or zero entry means that the quantity is not temperature-dependent. 3. TIDi refer to table data defined by TABLEM1, TABLEM2, TABLEM3 or TABLEM4 entries. 4. The material property computation depends on the TABLEMi entry selected. 7 BULK 7-206 BULK DATA UAI/NASTRAN