Overview of alarms
NCK alarms/ISO alarms
16694
Channel %1 block %2 following axis/spindle %3 status/instruction %4 is
not possible.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Status, instruction
Definitions:
The stated instruction is not permitted for the current status of the generic coupling.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
16695
Channel %1 block %2 following axis/spindle %3 status/instruction %4 is
not possible.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Status, instruction
Definitions:
The stated instruction is not permitted for the current status of the generic coupling.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part program.
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
16696
Channel %1 block %2 following axis/spindle %3 coupling has not been
defined.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
An instruction to an undefined coupling is to be executed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part programm.
Define the coupling and activate, if necessary, before the instruction.
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
16697
Channel %1 block %2 following axis/spindle %3 coupling has not been
defined.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
An instruction to an undefined coupling is to be executed.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part programm.
Define the coupling and activate, if necessary, before the instruction.
Program Continuation:
Clear alarm with NC START or RESET key and continue the program.
" Siemens AG 2007 All Rights Reserved