Download Siemens SINUMERIK 802D sl Specifications

Transcript
Overview of alarms
06/2007
NCK alarms/ISO alarms
Remedy:
Repeat entry with correct value and then Reset.
Program Continuation:
Teileprogramm neu starten.Clear alarm with the RESET key in all channels of this mode group.
Restart part program.
26017
Axis %1 machine data %2[%3] invalid value
Parameters:
%1 = axis name, spindle number
%2 = string: MD identifier
%3 = index: MD array index
Definitions:
Machine data contains an invalid value.
Reaction:
NC not ready.
The NC switches to follow-up mode.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Repeat entry with correct value and then Reset.
Program Continuation:
Teileprogramm neu starten.Clear alarm with the RESET key in all channels of this mode group.
Restart part program.
26018
Axis %1 setpoint output drive %2 used more than once
Parameters:
%1 = axis name, spindle number
%2 = drive number
Definitions:
A setpoint has been selected more than once.
The MD 30110 CTRLOUT_MODULE_NR contains the same value for different axes.
Reaction:
Mode group not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
Avoid duplicate setpoint assignment by correcting MD 30110 CTRLOUT_MODULE_NR
Program Continuation:
Switch control OFF - ON.
26019
Axis %1 encoder %2 measurement not possible with this controller
module
Parameters:
%1 = NC axis number
%2 = encoder number
Definitions:
If the MD 13100 DRIVE_DIAGNOSIS[8] contains a value not equal to zero, then the control has found
at least one control module which does not support measuring. Measuring was programmed from the
part program for the associated axis.
Reaction:
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
If possible, modify the measuring motion in such a manner that the axis concerned does not have to
travel; do not program this axis in the MEAS block again. However, it is then no longer possible to
query a measured value for this axis. Otherwise, exchange the controller module for one that supports
measuring. See MD 13100 DRIVE_DIAGNOSIS[8].
Program Continuation:
Clear alarm with the RESET key. Restart part program
2-260
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition