Download Siemens SINUMERIK 802D sl Specifications

Transcript
06/2007
List of action numbers
No. 122, TEST_SYNC_ASYNC
Explanation
Only for test purposes and only in Assert systems
Cause
-
Remedy
-
No. 123, START_LOCK
Explanation
PI _N_STRTLK Set global start disable
Cause
-
Remedy
-
No. 124, START_UNLOCK
Explanation
PI _N_STRTUL Reset global start disable
Cause
-
Remedy
-
No. 125, FASTMODESWITCHTOAHANDMODE
Explanation
Implicit change of operating mode to Jog at the beginning of a Jog motion in Automatic
mode
See also $MN_JOG_MODE_MASK
Cause
1. A channel has exited the mode group due to an interrupt.
2. Overstore
Remedy
− Abort the program with the Reset key or wait until the interrupt is terminated
− Deselect overstore
No. 126, FASTMODESWITCHTOAPROGMODE
Explanation
Implicit change of operating mode to Automatic at the end of a Jog motion in Automatic
mode
See also $MN_JOG_MODE_MASK
Cause
1. A channel has exited the mode group due to an interrupt.
2. Overstore
Remedy
− Abort the program with the Reset key or wait until the interrupt is terminated
− Deselect overstore
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
3-363