Download STARTUP HANDBOOK
Transcript
Step 7 Performing CAL (calibration) (for **-D series and XYC series only) CAL stands for calibration, which actuates all robot axes to move the robot arm in small motions in order to confirm the current arm position after the controller power is turned ON. The CAL procedure is described below. Remarks For the **-E/-F/-G series (except XYC series) and VM-6083D/-60B1D robots, skip Step 7 since no CAL is required. (Performing CAL even for those robots generates no problem.) Only the **-D series and XYC series require CAL to run the robot using accurate values. Caution Performing CAL will move the robot arm. Before proceeding, be sure that all workers have left the robot’s restricted space and that there are no obstacles in the robot’s restricted space. F6 Step 8 c Press [F6 Aux.] with the [Current Robot Position] window displayed. Selecting Manual mode and running the robot manually c Press [M-MOD]. The [Operation Mode] window is displayed. 7-13